Specifications | |
471M41H31 | for 4 to 32 sensors |
| contact form | N.O./N.O. |
| operating voltage | 24 V DC ±15% |
| max. current consumption | 850 mA |
| max. switching voltage | 30 V AC/DC |
| max. switching current | 3 A |
| max. switching power | 90 VA/W |
| temperature range | 0…+55°C |
| sensor inputs | 4 |
| safety outputs | 4 |
| operating time | 3 s |
| operating time 2-hand control unit | 0,5 s |
| switching voltage control output | 24 V DC |
| switching current control output | 100 mA |
| switching power control output | 2,4 W |
| safety characteristics | SIL CL: 3 / PL: e / cat.: 4 |
| PFHd (1/h) | 1,70e-8 |
| ETL-approved | e |
| Interface for this control unit | 364 097 for 4 sensors |
|
| Interface for this control unit | 363 V98 for 8 sensors |
|
| Emergency stop push button | NHTO1D (sealed to IP69K) |