| Order Code:471 M41 H31 |  | ELOBAU Safety Systems
Safety Systems Control Units to SIL CL 2 (IEC 62061) with N.O. - N.O. contact system.
Designed for 4/32 sensors 471M41H31
A maximum of 32 sensors may be used with an interconnection system.
Specifications | | 471M41H31 | for 4 to 32 sensors | | contact form | N.O./N.O. | | operating voltage | 24 V DC ±15% | | max. current consumption | 850 mA | | max. switching voltage | 30 V AC/DC | | max. switching current | 3 A | | max. switching power | 90 VA/W | | temperature range | 0…+55°C | | sensor inputs | 4 | | safety outputs | 4 | | operating time | 3 s | | operating time 2-hand control unit | 0,5 s | | switching voltage control output | 24 V DC | | switching current control output | 100 mA | | switching power control output | 2,4 W | | safety characteristics | SIL CL: 3 / PL: e / cat.: 4 | | PFHd (1/h) | 1,70e-8 | | ETL-approved | e | | Interface for this control unit | 364 097 for 4 sensors | |
| Interface for this control unit | 363 V98 for 8 sensors | |
| Emergency stop push button | NHTO1D (sealed to IP69K) |
Images and information are copyright of elobau GmbH & Co. KG | |

|
| |
| Supplier: | elobau GmbH & Co. KG |
| Packaging: | 1 |
| Min. Order: | 1 |
|