CANBUS, Safety, Custom Controls-Machinery Safety Systems-ELOBAU Safety Systems-Control Units - SIL CL 2 (NO/NO)

Eleobau 463111B1 Safety Control unit
ELOBAU Safety Control unit for 1 to 8 sensors plus "emergency stop"
Order Code:463 111 B1

   
ELOBAU Configurable Safety Systems
A free copy of the ELOBAU Safety Systems DVD awaits you.
To send an email. (remember to include your name and address)
Contract Engineering Services Contact Hassan Hamidi Ph 09 630 7871

Safety Systems Control Units to SIL CL 2 (IEC 62061) with N.O. - N.O. contact system.


Specifications

463 111 B1

Safety control unit

contact formN.O./N.O.
operating voltage24 V DC ±10%
max. current consumption90 mA
max. switching voltage250 V AC/30 V DC
max. switching current3 A
max. switching power750/90 VA/W
temperature range0…+55°C
sensor inputs1
safety outputs2
operating time3 sec
safety characteristicsSIL CL: 2 / PL: d / cat.: 3
PFHd (1/h)1,78e-8
ETL-approvedyes
  
Interface for this control unit363 V97 for 4 sensors
Interface for this control unit363 V99 for 8 sensors

Images and information are copyright of elobau GmbH & Co. KG


Supplier:elobau GmbH & Co. KG
Packaging:1
Min. Order:0